230 kV Transmission Line
Mandalay Division
Sr. |
Name of Transmission Line |
Conductor Size |
Distance (Mile) |
Number of Tower |
1 |
230 kV Myingyan (Steelmill) - Thapyaywa |
605 MCM |
53.46 |
263 |
2 |
230 kV Thazi - Thapyaywa |
605 MCM |
15.65 |
86 |
3 |
230 kV Yeywa - Thapyaywa |
795 MCM |
69.75 |
319 |
4 |
230 kV Belin - Thapyaywa |
795 MCM |
54.65 |
245 |
5 |
230 kV Shwesaryan - Belin |
795 MCM |
17.14 |
78 |
6 |
230 kV Yeywa - Belin |
795 MCM |
24.33 |
120 |
7 |
230 kV Shwesaryan - Myaukpyin |
605 MCM |
16.26 |
84 |
8 |
230 kV Myingyan (Sembcorp) In/Out |
605 MCM |
1.39 |
8 |
132 kV Transmission Line
Mandalay Division
Sr. |
Name of Transmission Line |
Conductor Size |
Distance (Mile) |
Number of Tower |
1 |
132 kV Kalaw - Yepaungsone |
397.5 MCM |
23.69 |
95 |
2 |
132 kV Yepaungsone - Thazi |
397.5 MCM |
21.49 |
108 |
3 |
132 kV Thazi - Belin |
336.4 MCM |
62.88 |
332 |
4 |
132 kV Belin - Tagondine |
336.4 MCM |
22.21 |
108 |
5 |
132 kV Shwesaryan - Yadanarpon |
397.5 MCM |
11.37 |
64 |
6 |
132 kV Yadanarpon – Pyin Oo Lwin |
397.5 MCM |
9.64 |
58 |
7 |
132 kV Tagondine - Shwesaryan |
397.5 MCM |
11.66 |
68 |
8 |
132 kV Kinda - Thazi |
300 sqmm |
45.40 |
227 |
9 |
132 kV Sedawgyi - Aungpinlae |
336.4 MCM |
30.20 |
158 |
10 |
132 kV Aungpinlae - Tagondine |
336.4 MCM |
6.55 |
38 |
11 |
132 kV Sedawgyi - Kyaukphahtoe |
397.5 MCM |
131.63 |
643 |
12 |
132 kV Kinda - Ingone |
336.4 MCM |
29.16 |
148 |
13 |
132 kV Ingone - Belin |
336.4 MCM |
12.68 |
64 |
14 |
132 kV Belin - Aungpinlae |
336.4 MCM |
24.75 |
131 |
15 |
132 kV Thazi - Myingyan |
397.5 MCM |
65.20 |
334 |
16 |
132 kV Ingone - Taungdawkwin |
397.5 MCM |
6.60 |
33 |
17 |
132 kV Myingyan – Sunlun |
605 MCM |
3.05 |
17 |
18 |
132 kV Yepaungsone - Yinmarpin |
397.5 MCM |
0.57 |
5 |
66 kV Transmission Line
Mandalay Division
Sr. |
Name of Transmission Line |
Conductor Size |
Distance (Mile) |
Number of Tower |
1 |
66 kV Nyaungoo - Myingyan |
185 sqmm |
36.33 |
472 |
2 |
66 kV Myingyan - Hsimeegone (2) |
397.5 MCM |
17.02 |
273 |
3 |
66 kV Hsimeegone (2) - Ywathit |
397.5 MCM |
24.52 |
403 |
4 |
66 kV Ywathit - Kyauktalone |
397.5 MCM |
8.60 |
139 |
5 |
66 kV Myingyan – Nbui (Truck Axial Factory) |
185 sq mm |
17.50 |
316 |
33 kV Transmission Line
Mandalay Division
Sr. |
Name of Transmission Line |
Conductor Size |
Distance (Mile) |
Number of Tower |
1 |
33 kV Kyaukse (GT) - Belin |
397.5 MCM |
7 |
66 |
230 kV Primary Substation (Mandalay Division) (2022, August)
No |
Substation |
Voltage ratio |
Capacity (MVA) |
Total Capacity (MVA) |
Location |
1 |
Myingyan (Steel Mill) |
230/33/11 kV |
85 |
255 |
Myingyan District, Myingyan Township |
230/33/11 kV |
85 |
||||
230/11 kV |
85 |
||||
2 |
Myaukpyin |
230/33/11 kV |
100 |
300 |
Aungmyatharzan Township |
230/33/11 kV |
100 |
||||
230/33/11 kV |
100 |
||||
3 |
Shwesaryan |
230/132/11 kV |
100 |
410 |
Patheingyi Township |
230/33/11 kV |
60 |
||||
230/33/11 kV |
100 |
||||
230/33/11 kV |
150 |
||||
4 |
Thapyawa |
230/33/11 kV |
60 |
180 |
Meikhtila District, Thazi Township, Thapyawa village |
230/33/11 kV |
60 |
||||
230/66/11 |
60 |
||||
5 |
Thazi |
230/132/11 kV |
100 |
260 |
Meikhtila District, Thazi |
230/132/11 kV |
100 |
||||
132/33/11 kV |
30 |
||||
132/33/11 kV |
30 |
||||
6 |
Belin |
230/132/11 kV |
100 |
200 |
Sint-kine Township, Kyaukse District |
132/33/11 kV |
100 |
||||
7 |
Aungpinlae |
230/132/11 kV |
100 MVA |
231.5 |
Pa-thein-gyi Township |
132/11 kV |
31.5 MVA |
||||
230/33/11 kV |
100 MVA |
||||
Total capacity (MVA) |
1836.5 |
|
132 kV Primary Substation (Mandalay Division) (2022, August)
No |
Substation |
Voltage ratio |
Capacity (MVA) |
Total Capacity (MVA) |
Location |
1 |
Tagondine |
132/33/11 kV |
100 |
250 |
Pyigyitagon Township |
132/33/11 kV |
100 |
||||
132/33/11 kV |
50 |
||||
2 |
Myingyan |
132/66/11 kV |
45 |
90 |
Myingyan Township |
132/66/11 kV |
45 |
||||
3 |
Yinmarbin |
132/33/11 kV |
10 |
10 |
Thazi Township, Meikhtila District |
4 |
Yatanabon |
132/33/11 kV |
30 |
48 |
Pyinoolwin Township, YadanarponMyoe-thit |
132/33/11 kV |
18 |
||||
5 |
Yepaungsone |
132/33/11 kV |
60 |
160 |
Thazi Township, Meikhtila District |
132/33/11 kV |
50 |
||||
132/33/11 kV |
50 |
||||
6 |
Lattpanhla |
132/33/11 kV |
20 |
80 |
Sinkuu Township, Pyinoolwin District |
132/66/11 kV |
60 |
||||
7 |
Ingone |
132/33/11 kV |
60 |
60 |
Kyaukse Township, Kyaukse District |
8 |
Anesakhan |
132/33/11 kV |
60 |
140 |
Pyinoolwin District, Pyinoolwin Township, |
132/33/11 kV |
80 |
||||
9 |
Taungdawkwin |
132/33/11 kV |
50 |
150 |
Kyaukse District, Kyaukse Township |
132/33/11 kV |
50 |
||||
132/33/11 kV |
50 |
||||
Total capacity (MVA) |
988 |
|
1. 230 kV Myingyan (Steel Mill) Primary Substation)
1.Location
Myingyan Township, Myingyan District Mandalay Division
2. Area
(6) Arce
3. Commissioning Date
(4-September-2008)
230/33/11 kV 85 MVA (Tamini, Italy)
230/33/11 kV 85 MVA (LEEEC, China)
230/11 kV 85 MVA (LEEEC, China)
Total 255 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Thapyaywa Line
(2) Sembcorp Line
(B) 33 kV Distribution Feeders
(1) Electric Arc Furnace
(2) Laddle Refining Furnace Feeder
(3) Statistic Var Compensator Feeder
(4) Electric Arc Furnace Feeder
(5) Laddle Refining Furnace Feeder
(6) Statistic Var Compensator Feeder
(C) 11 kV Distribution Feeders
(1) Melting Shop Feeder
(2) Continuous Casting Machine-1 Feeder
(3) Continuous Casting Machine-2 Feeder
(4) Water Treatment Plant-1 Feeder
(5) Water Treatment Plant-2 Feeder
(6) Fume Treatment Plant Feeder
(7) Air Separation Plant Feeder
(8) Admin Feeder
(9) Tube Well Feeder
(10) Fire Services Feeder
6.Distribution Regions
No (1) Myingyan (Steel Mill)
2. 230 kV Myaukpyin Primary Substation
1. Location
Patheingyi Township, Mandalay District, Mandalay Division
2. Area
(36.67) Acre
3. Comissioning Date
(29-February-2012)Transformer No- (1) & (2)
(12-April-2017)Transformer No- (3)
4 Install Capacity
230/33/11 kV 100 MVA (LEEEC, China)
230/33/11 kV 100 MVA (LEEEC, China)
230/33/11 kV 100 MVA (ABB, Thailand)
Total 300 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Shwesaryan Line
(B) 33 kV Distribution Feeders
(1) Din-gar-chaung –1 Feeder
(2) Din-gar-chaung –2 Feeder
(3) Ma-yan-chan-1 Feeder
(4) Ma-yan-chan-2 Feeder
(5) Shwe-kyaun-gyi Feeder
(6) Oh-bo Feeder
(7) Hay-mar-za-la Feeder
(8) Nyaung-kwe Feeder
(9) Ei-to Feeder
(10)War-khine-gone Feeder
(11) Tait-taw Feeder
(12) (76) Street Feeder
(13) Water Supply (MCDC) Feeder
(14) Mingalar Mandalay Feeder
(15) MaHarAungMyay Feeder
(16) AungMyay ManDaLar Feeder
6. Distribution Regions
Aungmyaetharzan Township, Chanayetharzan Township,
Maharaungmyae Township, Patheingyi Township and Matayar Township
3. 230 kV Shwesaryan Primary Substation
1. Location
Patheingyi Township, Mandalay District, Mandalay Division
2. Area
(41.42) Acre
3. Commissioning Date
(31-July-2008)
4 Install Capacity
230/132/11 kV 100 MVA (Areva, China)
230/33/11 kV 60 MVA (LEEEC, China)
230/33/11 kV, 100 MVA (ABB, Thiland)
230/33/11 kV, 150 MVA (AG, Myanmar)
Total 410 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Mansan (1) Line
(2) Mansan (2) Line
(3) Belin (1) Line
(4) Belin (2) Line
(5) Aungpinlae Line
(B) 132 kV Transmission Lines
(1) Pyinoolwin Line
(2) Tagontaing Line
(C) 33 kV Distribution Feeder
(1) Shwe-lan-bo Feeder
(2) Pa-thein-gyi Feeder
(3) Pyi-gyi-ta-gon Feeder
(4) Chan-mya-Tharzi Feeder
(5) feeder-5 Kyauk Me feeder
(6) feeder-6 Myayenadar feeder
(7) Steel Mill (1) Feeder
(8) Steel Mill (2) Feeder
(9) Steel Mill (3) Feeder
(10) Steel Mill (4) Feeder
6. Distribution Regions
Shwe-lan-bo, Patheingyi Township, Chanmyatharzi Township and Pyigyitagon Township
4. 230 kV Thapyaywa Primary Substation
1. Location
Thapyaywa Village, Tharzi Township, Meikhtila District, Mandalay Division
2. Area
(48.28) Acre
3. Commissioning Date
(27-December-2008)
4. Transformer Capacity
230/33/11 kV 60 MVA (LEEEC, China)
230/33/11 kV 60 MVA (Siemens, China)
230/33/11 kV 60 MVA (Chint, China)
Total 180 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Belin (1) Line
(2) Belin (2) Line
(3) Yeywa (1) Line
(4) Yeywa (2) Line
(5) Tharzi Line
(6) Myingyan (Steel) Line
(7) Taungdwingyi Line
(B) 33 kV Distribution Feeders
(1) Aung-San Feeder
(2) Shan-Tel Feeder
(3) Industrial Zone Feeder
(4) Win-dwin eeder
(5) Ta-ka-sa (10) Factory Feeder
(6) Ta-ka-sa (10) Residential Feeder
(7) Ta-ka-sa (1) Textile Feeder Feeder
(8) Won-Zin Feeder
(9) Solar Feeder
(10) Army Textile Factory Feeder
(11) Water Resources Feeder
6. Distribution Regions
MeikhtilaTwnship, Quarters, Villages and Battalion and corps within Meikhtila District
5. 230 kV Thazi Primary Substation
1. Location
Thazi Township, Meikhtila District, Mandalay Division
2. Area
(55.71) Acre
3. Commissioning Date
(11-December-1963)
4. Transformer Capacity
230/132/11 kV 100 MVA (Areva, China)
230/132/11 kV 100 MVA (Areva, China)
132/33/11 kV 30 MVA (Hyosung, Korea)
132/33/11 kV 30 MVA (Trafounion, Germany)
Total 260 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Shwemyo Line
(2) Thapyaywa Line
(B) 132 kV Transmission Lines
(1) Yepaungsoan (1) Line
(2) Yepaungsoan (2) Line
(3) Belin Line
(4) Kin-Tarr Line
(5) Chauk Line
(6) Myingyan Line
(C) 33 kV Distribution Feeders
(1) Army Textile Factory Feeder
(2) (999) + Water Resource Feeder
(3) Hlaing-Tat Feeder
(4) Fa-Lan-Kyin Feeder
(5) Pa-La-Sa (3) Feeder
(6) Pyaw-Bwe (Textile) Feeder
(7) Thazi Feeder
(8) Pyaw-Bwe Feeder
(9) Army CanvasFactoryFeeder
(10) MakeHtiLar New Feeder
6. Distribution Regions
Mandalay Division, Meikhtila District, Tharzi Township, Wan-Twin Township,
Ya-Mell-Thin District, Pyaw-Bwe Township
6. 230 kV Belin Primary Substation
1. Location
Mandalay Division, Kyaukse District, Sint-kine Township
(79.89) Acre
3. Commissioning Date
(31-July-2008)
4 Install Capacity
230/132/11 kV 100 MVA (Areva, China)
230/33/11 kV 100 MVA (Alstom, India)
Total 200 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Shwesaryan (1) Line
(2) Shwesaryan (2) Line
(3) Thapyaywa (1) Line
(4) Thapyaywa (2) Line
(5) Yeywa (1) Line
(6) Yeywa (2) Line
(7) Owntaw (1) Line
(8) Owntaw (2) Line
(B) 132 kV Transmission Lines
(1) Aungpinlae Line
(2) Tagondine Line
(3) Thazi Line
(4) Inngone Line
(5) PGK Gas Engine
(C) 33 kV Distribution Feeders
(1) Kyaukse Feeder
(2) Dattaw Feeder
(3) Sin-min-3 Feeder
(4) MOGE Feeder
(5) Sint-kine Feeder
(6) APR Gas Engine
(7) PGK Gas Engine
(8) Steel Mill Feeder
(9) Than Taung Oo Feeder
6. Distribution Regions
Kyaukse Township, Sintkine Township, Palate Town, Tadaroo Township and Amarapura Township
7. 230 kV Aungpinlae Primary Substation
1. Location
Pa-thein-gyi Township, Mandalay District, Mandalay Division
2. Area
(22.52) Acre
3. Commissioning Date
(19-July-1995)
4. Installed Capacity
230/132/11 kV 100 MVA (Seimen, Germany)
230/33/11 kV 100 MVA (ABB, Thailand)
132/11 kV 31.5 MVA (Changzhou, China)
Total 231.5 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) MyaukPyin Line
(2) ShweSar Yan Line
(B) 132 kV Transmission Lines
(1) Sedawgyi Line
(2) Belin Line
(3) Tagontaing Line
(C) 33 kV Distirbution Feeders
(1) Myoe-ma Feeder
(2) Industrial Training Center Feeder
(3) Htun-don Feeder
(4) War-khin-gone Feeder
(5) War-khin-gone-2 Feeder
(D) 11 kV Distribution Feeders
(1) Nanshae Feeder
(2) (26) Street Feeder
(3) (28) Street Feeder
(4) (35) Street Feeder
(5) Mandalay Technical University Feeder
(6) (30) Street Feeder
(7) MaHarMyaing Feeder
6. Distribution Regions
Aung-myay-tharzan Township, Chan-aye-tharzan Township, Mahar-aung-myay
Township, Chan-mya-tharzi Township, Pa-thein-gyi Township
1. 132 kV Tagondine Primary Substation
1. Location
Pyigyitagon Township, Mandalay District, Mandalay Division
2. Area
(40.30) Acre
3. Commissioning Date
(11-December-1963)
4. Installed Capacity
132/33/11 kV 100 MVA (AG, Myanmar)
132/33/11 kV 100 MVA (AG, Myanmar)
132/33/11 kV 50 MVA (Chint, China)
Total 250 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Belin Line
(2) Shwesaryan Line
(3) Aungpinlae Line
(B) 33 kV Distribution Feeders
(1) Palake Feeder
(2) Airport (Preferential) Feeder
(3) Airport (Spare) Feeder
(4) Sagaing Feeder
(5) Dairy Feeder
(6) Industrial Zone (2) Feeder
(7) Bar-gayar Feeder
(8) Playground Feeder
(9) Thin-pan-gone Feeder
(10) Chipar Feeder
(11) CNPC Feeder
(12) Grand Park Feeder
(13) Garden City Feeder
6. Distribution Regions
Pyigyitagon Township, Chanmyatharze Township, Amarapura Township,
Maharaungmyay Township, Palake Township, Dan-dar-oo Township
2. 132 kV Myingyan Primary Substation
1. Location
Myingyan Township, Myingyan District, Mandalay Division
2. Area
(7) Acre
3. Commissioning Date
(25-July-2007)
4. Installed Capacity
132/66/11 kV, 45 MVA (Crompton Greave, India)
132/66/11 kV, 45 MVA (Crompton Greave, India)
Total 90 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Thazi Line
(2) V-power Line
(B) 66 kV Transmission Lines
(1) Nyaung-oo Electric River Pump Line
(2) Seik-nyan Electric River Pump Line
(3) Se-mee-Khong (1) River Pump Line
(4) Se-mee-Khong (2) River Pump Line
(5) Kyaw-ze Line
(6) Na-bu-I (Ministry of Industry) Line
(7) TaungThar Line
(C) 33 kV Distribution Feeders
(1) Steel Mill Feeder
(2) Thar-paung River Pump Feeder
(3) Myingyan (2) Feeder
(4) Na-htoe-gyiFeeder
(5) MOGE Feeder
(6) ThaungThar-MaHlaing Feeder
6. Distribution Regions
River Pumps in MyingyanTownship, Taung-thar, Ma-hlaing, Na-htoe-gyi, Nga-zoon,
Myit-thar, Nyaung-oo Townships, River Pumps in Bagan Township, Myaung Township,
Twin-gyi River Pump, Na-bu-I Factory, Myo-thar, Myingyan Industrial Zone
3. 132 kV Yinmarpin Primary Substation
1. Location
Near Yinmarpin Cottage Village, ThaziTownship, Meikhtila District, Mandalay Division
2. Area
(20) Acre
3. Commissioning Date
(25-November-2006)
4. Installed Capacity
132/33/11 kV, 10 MVA (Mitsubishi, Japan)
Total 10 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Yepaungsone Line
(B) 33 kV Distribution Feeders
(1) Engine Plant Feeder
(2) Ta-Ka-Sa (2) Feeder
6. Distribution Regions
No (2) Army Heavy Industry Factory, Yinmarpin Cottage, Thazi Township
4. 132 kV Yadanarpon Primary Substation
1. Location
YadanarponMyoe-thit, Pyinoolwin District, Mandalay Division
2. Area
(10.8) Acre
3. Commissioning Date
(29-November -2007)
4.Installed Capacity
132/33/11 kV, 30 MVA (Mitsubishi, Japan)
132/33/11 kV, 18 MVA (Areva, Indonesia)
Total 10 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Shwesaryan Line
(B) 33 kV Distribution Feeders
(1) Northern Residential Feeder
(2) 21 mile Feeder
(C) 11 kV Distribution Feeders
(1) Teleport Feeder
(2) Incubation Feeder
(3) SoftbaseFeeder
6. Distribution Regions
Yadanarpon Teleport, Electronic product Factory, Northern Residential, 21 mile village, Central
Service of Civil Institude,Pyin-sar village, Thone-daung village, Communication Tower, Teleport Southern
Residential, Cyber Hall,Police Training Center, YadanarponMyoe-thitNorthern Residential (200 Acre)
5. 132 kV Yepaungsone Primary Substation
1. Location
Thazi Township, Meikhtila District, Mandalay Division
2. Area
(61.7) Acre
3. Commissioning Date
(21-February -2010)
4. Installed Capacity
132/33/11 kV 60 MVA (BaogingTianwei, China)
66/11 kV 50 MVA (ABB, Thailand)
132/66/11 kV 50 MVA (ABB, Thailand)
Total 160 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Kalaw (1) Line
(2) Kalaw (2) Line
(3) Thazi (1) Line
(4) Thazi (2) Line
(5) Yinmarpin Line
(B) 66 kV Distribution Feeders
(1) Shwedaung Cement Factory Feeder-1
(2) Shwedaung Cement Factory Feeder-2
(B) 33 kV Distribution Feeders
(1) Htoo Cement Factory Feeder
(2) Shwe-daung Cement Factory Feeder
(3) YCDC Feeder
(4) Pyin-yaung Village Feeder
(5) Yinmarpin Village Feeder
6. Distribution Regions
Cement Factories, Villages
6. 132 kV Lattpanhla Primary Substation
1. Location
Sin-gu Township, Pyinoolwin District, Mandalay Division
(20.03) Acre
3. Commissioning Date
(5-September -1997)
4.Installed Capacity
132/33/11 kV,20 MVA (Imefy, Spain)
132/66/11 kV, 60 MVA (Xina XD, China)
Total 80 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Sedawgyi Line
(2) Hnagpyawdine Line
(3) Shwe LI(3) Line
(B) 66 kV Distribution Lines
(1) Moe-gok Line
(C) 33 kV Distribution Feeders
(1) Moe-gok Feeder
(2) Sin-guu Feeder
(3) Kyauk-kyi Feeder
6. Distribution Regions
Mogok, Tha-bake-kyin, Kyauk-myaung, No (1) Science and Technology Battalion (Kyauk-kyi)
7. 132 kV Ingone Primary Substaion
1. Location
Kyaukse Township, KyaukseDistrict, Mandalay Division
2. Area
(10.25) Acre
3. Commissioning Date
(17-March -2003)
4. Installed Capacity
132/33/11 kV 60 MVA (Daihen, Japan)
Total 60 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Kin-dar Line
(2) Belin Line
(3) Taungdawkwin Line
(B) 33 kV Distribution Feeders
(1) MI-1(Pharm) Feeder
(2) Cotton yarn Feeder
(3) Taung-taw (Communication) Feeder
(4) MI-1(Industrial Zone) Feeder
(5) Sin-min Cement Factory Feeder
(6) Mechanized Farming Feeder
(7) Mine-maw (Tank Car) Feeder
(8) Phyuk-seik-pin Feeder
(9) Kyaukse (Mirror) Feeder
(10) Myit-thar+Kumae Feeder
(11) HanMyintMho Feeder
6. Distribution Regions
Southern part of Kyaukse, Myit-thar Township, Ku-mae Township, Northern part of Windwin Township,
Pharmaceutical Industry, Cotton yarn, Industry (1) Factories, Sin-min Cement Factory, Mechanized
Farming, Mirror Factory, Taung-taw (Communication), Phyuk-seik-pin Battalion, Min-Maw Cantonment
8. 132 kV Anaesakhan Primary Substation
1. Location
Pyinoolwin Township, Pyinoolwin District, Mandalay Division
2. Area
(33.17) Acre
3. Commissioning Date
(20-November -1983)
4. Installed Capacity
132/33/11 kV, 60 MVA (Areva, Indonesia)
132/33 kV, 80 MVA (Hawker Siddeley, England)
Total 140 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Shwesaryan- Yadanarpon- Anaesakhan Line
(B) 33 kV Distribution Feeders
(1) Iron and Steel Mill (1) Feeder
(2) Iron and Steel Mill (2) Feeder
(3) Pyinoolwin Feeder
(4) Tat-tnal Feeder
(5) Ta-Tha-Na Feeder
(6) Pharmaceutical Industry Feeder
(7) Tha-Pa-Na Feeder
(8) Athanlwint Feeder
(9) Kyuntapin Feeeder
(C) 11 kV Distribution Feeders
(1) Si-thar (1) Feeder
(2) Si-thar (2) Feeder
(3) Kan-taw-gyi + Residential Feeder
(4) THS Feeder
6. Distribution Regions
Pyinoolwin
9. 132 kV Taungdawkwin Primary Substation
1. Location
Kyaukse Township, Kyaukse District, Mandalay Division
2. Area
(38.224) Acre
3. Commissioning Date
(3-November-2012)
4. Installed Capacity
132/33/11 kV 50 MVA (Siemens, China)
132/33/11 kV 50 MVA (Siemens, China)
132/33/11 kV 50 MVA (Siemens, China)
Total 150 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Ingone Line
(B) 33 kV Distribution Feeders
(1) AAA (Cement) Feeder
(2) Tiger Head (Cement) Feeder
(3) Myanmar Elephant (Cement) Feeder
(4) Than-taw-myatFeeder
(5) Myoe-gyi (1) Feeder
(6) Myoe-gyi (2) Feeder
6. Distribution Regions
Ywar-Ngan Township, Kyaukse Township
Mandalay Division
Sr. |
Name of Transmission Line |
Conductor Size |
Distance (Mile) |
Number of Tower |
1 |
230 kV Myingyan (Steelmill) - Thapyaywa |
605 MCM |
53.46 |
263 |
2 |
230 kV Thazi - Thapyaywa |
605 MCM |
15.65 |
86 |
3 |
230 kV Yeywa - Thapyaywa |
795 MCM |
69.75 |
319 |
4 |
230 kV Belin - Thapyaywa |
795 MCM |
54.65 |
245 |
5 |
230 kV Shwesaryan - Belin |
795 MCM |
17.14 |
78 |
6 |
230 kV Yeywa - Belin |
795 MCM |
24.33 |
120 |
7 |
230 kV Shwesaryan - Myaukpyin |
605 MCM |
16.26 |
84 |
8 |
230 kV Myingyan (Sembcorp) In/Out |
605 MCM |
1.39 |
8 |
Mandalay Division
Sr. |
Name of Transmission Line |
Conductor Size |
Distance (Mile) |
Number of Tower |
1 |
132 kV Kalaw - Yepaungsone |
397.5 MCM |
23.69 |
95 |
2 |
132 kV Yepaungsone - Thazi |
397.5 MCM |
21.49 |
108 |
3 |
132 kV Thazi - Belin |
336.4 MCM |
62.88 |
332 |
4 |
132 kV Belin - Tagondine |
336.4 MCM |
22.21 |
108 |
5 |
132 kV Shwesaryan - Yadanarpon |
397.5 MCM |
11.37 |
64 |
6 |
132 kV Yadanarpon – Pyin Oo Lwin |
397.5 MCM |
9.64 |
58 |
7 |
132 kV Tagondine - Shwesaryan |
397.5 MCM |
11.66 |
68 |
8 |
132 kV Kinda - Thazi |
300 sqmm |
45.40 |
227 |
9 |
132 kV Sedawgyi - Aungpinlae |
336.4 MCM |
30.20 |
158 |
10 |
132 kV Aungpinlae - Tagondine |
336.4 MCM |
6.55 |
38 |
11 |
132 kV Sedawgyi - Kyaukphahtoe |
397.5 MCM |
131.63 |
643 |
12 |
132 kV Kinda - Ingone |
336.4 MCM |
29.16 |
148 |
13 |
132 kV Ingone - Belin |
336.4 MCM |
12.68 |
64 |
14 |
132 kV Belin - Aungpinlae |
336.4 MCM |
24.75 |
131 |
15 |
132 kV Thazi - Myingyan |
397.5 MCM |
65.20 |
334 |
16 |
132 kV Ingone - Taungdawkwin |
397.5 MCM |
6.60 |
33 |
17 |
132 kV Myingyan – Sunlun |
605 MCM |
3.05 |
17 |
18 |
132 kV Yepaungsone - Yinmarpin |
397.5 MCM |
0.57 |
5 |
Mandalay Division
Sr. |
Name of Transmission Line |
Conductor Size |
Distance (Mile) |
Number of Tower |
1 |
66 kV Nyaungoo - Myingyan |
185 sqmm |
36.33 |
472 |
2 |
66 kV Myingyan - Hsimeegone (2) |
397.5 MCM |
17.02 |
273 |
3 |
66 kV Hsimeegone (2) - Ywathit |
397.5 MCM |
24.52 |
403 |
4 |
66 kV Ywathit - Kyauktalone |
397.5 MCM |
8.60 |
139 |
5 |
66 kV Myingyan – Nbui (Truck Axial Factory) |
185 sq mm |
17.50 |
316 |
Mandalay Division
Sr. |
Name of Transmission Line |
Conductor Size |
Distance (Mile) |
Number of Tower |
1 |
33 kV Kyaukse (GT) - Belin |
397.5 MCM |
7 |
66 |
No |
Substation |
Voltage ratio |
Capacity (MVA) |
Location |
1 |
Myingyan (Steel Mill) |
230/33/11 |
85 |
Myingyan District, Myingyan Township |
230/33/11 |
85 |
|||
230/11 |
85 |
|||
2 |
Myauk pyin |
230/33/11 |
100 |
Aungmyatharzan Township |
230/33/11 |
100 |
|||
230/33/11 |
100 |
|||
3 |
Shwesaryan |
230/132/11 |
100 |
Patheingyi Township |
230/33/11 |
60 |
|||
4 |
Thapyawa |
230/33/11 |
60 |
Meikhtila District, Thazi Township, Thapyawa village |
230/33/11 |
60 |
|||
5 |
Thazi |
230/132/11 |
100 |
Meikhtila District, Thazi |
230/132/11 |
100 |
|||
132/33/11 |
30 |
|||
132/33/11 |
30 |
|||
6 |
Belin |
230/132/11 |
100 |
Kyaukse , Belin village |
132/33/11 |
30 |
|
||
132/33/11 |
30 |
|
No |
Substation |
Voltage ratio |
Capacity (MVA) |
Location |
1 |
Tagondine |
132/33 |
80 |
Pyigyitagon Township |
132/33/11 |
30 |
|||
132/11 |
50 |
|||
2 |
Myingyan |
132/66/11 |
45 |
Myingyan Township |
132/66/11 |
45 |
|||
3 |
Yinmarbin |
132/33 |
15 |
Yinmarbin Village, Yaepaungsone |
4 |
Yatanabon |
132/33/11 |
18 |
Pyinoolwin Township, Pyinsar village |
5 |
Yepaungsone |
132/33/11 |
60 |
Yinmarbin Village, Yaepaungsone |
6 |
Lattpanhla |
132/33/11 |
20 |
Pyinoolwin District, Sinkuu Township, Lattpanhla |
132/66/11 |
60 |
|||
7 |
Ingone |
132/33/11 |
60 |
Kyaukse Township, Inngone village |
8 |
Anesakhan |
132/33/11 |
60 |
Pyinoolwin District, Pyinoolwin Township, |
9 |
Aungpinlae |
132/33/11 |
30 |
Patheingyi Township |
132/11 |
31.5 |
|||
10 |
Taungdawkwin |
132/33/11 |
50 |
Kyaukse District, Kyaukse Township
|
132/33/11 |
50 |
|||
132/33/11 |
50 |
1. Location
Myingyan Township, Myingyan District Mandalay Division
2. Area
(6) Arce
3. Commissioning Date
(4-September-2008)
230/33/11 kV 85 MVA (Tamini, Italy)
230/33/11 kV 85 MVA (LEEEC, China)
230/33/11 kV 85 MVA (LEEEC, China)
Total 255 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Thapyaywa Line
(2) Sembcorp Line
(B) 33 kV Distribution Feeders
(1) Electric Arc Furnace
(2) Laddle Refining Furnace Feeder
(3) Statistic Var Compensator Feeder
(4) Electric Arc Furnace Feeder
(5) Laddle Refining Furnace Feeder
(6) Statistic Var Compensator Feeder
(C) 11 kV Distribution Feeders
(1) Melting Shop Feeder
(2) Continuous Casting Machine-1 Feeder
(3) Continuous Casting Machine-2 Feeder
(4) Water Treatment Plant-1 Feeder
(5) Water Treatment Plant-2 Feeder
(6) Fume Treatment Plant Feeder
(7) Air Separation Plant Feeder
(8) Admin Feeder
(9) Tube Well Feeder
(10) Fire Services Feeder
6. Distribution Regions
No (1) Myingyan (Steel Mill)
1. Location
Patheingyi Township, Mandalay District, Mandalay Division
2. Area
(36.67) Acre
3. Comissioning Date
(3-March-2012)Transformer No- (1) & (2)
(12-April-2017)Transformer No- (3)
4 Install Capacity
230/33/11 kV 100 MVA (LEEEC, China)
230/33/11 kV 100 MVA (LEEEC, China)
230/33/11 kV 100 MVA (ABB, Thailand)
Total 300 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Shwesaryan Line
(B) 33 kV Distribution Feeders
(1) Din-gar-chaung Feeder
(2) Ma-yan-chan Feeder
(3) Shwe-kyaun-gyi Feeder
(4) Oh-bo Feeder
(5) Hay-mar-za-la Feeder
(6) Nyaung-kwe Feeder
(7) Ei-to Feeder
(8) War-khine-gone Feeder
(9) Tait-taw Feeder
(10) (76) Street Feeder
(11) Water Supply (MCDC) Feeder
(C) 11 kV Distribution Feeders
(1) Station Used
(2) Residential
6. Distribution Regions
Aungmyaetharzan Township, Chanayetharzan Township, Maharaungmyae Township, Patheingyi Township and Matayar Township
1. Location
Patheingyi Township, Mandalay District, Mandalay Division
2. Area
(41.42) Acre
3. Commissioning Date
(31-July-2008)
4 Install Capacity
230/132/11 kV 100 MVA (Areva, China)
230/33/11 kV 60 MVA (LEEEC, China)
Total 160 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Mansan (1) Line
(2) Mansan (2) Line
(3) Belin (1) Line
(4) Belin (2) Line
(5) Myaukpyin Line
(B) 132 kV Transmission Lines
(1) Pyinoolwin Line
(2) Tagontaing Line
(C) 33 kV Distribution Feeder
(1) Shwe-lan-bo Feeder
(2) Pa-thein-gyi Feeder
(3) Pyi-gyi-ta-gon Feeder
(4) Chan-mya-Tharzi Feeder
6. Distribution Regions
Shwe-lan-bo, Patheingyi Township, Chanmyatharzi Township and Pyigyitagon Township
1. Location
Thapyaywa Village, Tharzi Township, Meikhtila District, Mandalay Division
2. Area
(48.28) Acre
3. Commissioning Date
(27-December-2008)
4. Transformer Capacity
230/33/11 kV 60 MVA (LEEEC, China)
230/33/11 kV 60 MVA (Siemens, China)
Total 120 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Belin (1) Line
(2) Belin (2) Line
(3) Yeywa (1) Line
(4) Yeywa (2) Line
(5) Tharzi Line
(6) Myingyan (Steel) Line
(7) Taungdwingyi Line
(B) 33 kV Distribution Feeders
(1)Wann-Zinn Feeder
(2) Shan-Tel Feeder
(3) Industrial Zone Feeder
(4) Win-dwin Feeder
(5) Ta-ka-sa (10) Factory Feeder
(6) Ta-ka-sa (10) Residential Feeder
(7) Ta-ka-sa (10) Textile Feeder
(8) Ta-ka-sa (1) Factory Feeder
6. Distribution Regions
Meikhtila Twnship, Quarters, Villages and Battalion and corps within Meikhtila District
1. Location
Thazi Township, Meikhtila District, Mandalay Division
2. Area
(55.71) Acre
3. Commissioning Date
(11-December-1963)
4. Transformer Capacity
230/132/11 kV 100 MVA (Areva, China)
230/132/11 kV 100 MVA (Areva, China)
132/33/11 kV 30 MVA (Hyosung, Korea)
132/33/11 kV 30 MVA (Trafounion, Germany)
33/11kV 5 MVA
Total 265 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Shwemyo Line
(2) Thapyaywa Line
(B) 132 kV Transmission Lines
(1) Yepaungsoan (1) Line
(2) Yepaungsoan (2) Line
(3) Belin Line
(4) Kin-Tarr Line
(5) Chauk Line
(6) Myingyan Line
(C) 33 kV Distribution Feeders
(1) Army Textile Factory Feeder
(2) (999) + Water Resource Feeder
(3) Hlaing-Tat Feeder
(4) Fa-Lan-Kyin Feeder
(5) Pa-La-Sa (3) Feeder
(6) Pyaw-Bwe (Textile) Feeder
(7)Thazi Feeder
(8) Pyaw-Bwe Feeder
6. Distribution Regions
Mandalay Division, Meikhtila District, Tharzi Township, Wan-Twin Township, Ya-Mell-Thin District, Pyaw-Bwe Township
1. Location
Mandalay Division, Kyaukse District, Sint-kine Township
2. Area
(79.89) Acre
3. Commissioning Date
(31-July-2008)
4 Install Capacity
230/132/11 kV 100 MVA (Areva, China)
230/33/11 kV 100 MVA (Alstom, India)
Total 200 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Shwesaryan (1) Line
(2) Shwesaryan (2) Line
(3) Thapyaywa (1) Line
(4) Thapyaywa (2) Line
(5) Yeywa (1) Line
(6) Yeywa (2) Line
(7) Owntaw (1) Line
(8) Owntaw (2) Line
(B) 132 kV Transmission Lines
(1) Aungpinlae Line
(2) Tagondine Line
(3) Thazi Line
(4) Ingone Line
(C) 33 kV Distribution Feeders
(1) Kyaukse Feeder
(2) Dattaw Feeder
(3) Sin-min Feeder
(4) MOGE Feeder
(5) Sint-kine Feeder
(6) APR Gas Engine
6. Distribution Regions
Kyaukse Township, Sintkine Township, Palate Town, Tadaroo Township and Amarapura Township
1. Location
Pyigyitagon Township, Mandalay District, Mandalay Division
2. Area
(40.30) Acre
3. Commissioning Date
(11-December-1963)
4. Installed Capacity
132/33 kV 80 MVA (Hawker Siddeley, England)
132/33/11 kV 30 MVA (Mitsubishi, Japan)
132/33/11 kV 50 MVA (Chint, China)
Total 160 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Belin Line
(2) Shwesaryan Line
(3) Aungpinlae Line
(B) 33 kV Distribution Feeders
(1) Palake Feeder
(2) Airport (Preferential) Feeder
(3) Airport (Spare) Feeder
(4) Sagaing Feeder
(5) Dairy Feeder
(6) Industrial Zone (2) Feeder
(7) Monkish Hospital Feeder
(8) Bar-gayar Feeder
(9) Playground Feeder
(10)Thin-pan-gone Feeder
(11) Chipar Feeder
(12) Oil and Gas Feeder
(13) Deluxe Hotel Feeder
(C) 11 kV Distribution Feeders
(1) Yeywa Guest-house Feeder
6. Distribution Regions
Pyigyitagon Township, Chanmyatharze Township, Amarapura Township, Maharaungmyay Township, Palake Township, Dan-dar-oo Township
1. Location
Myingyan Township, Myingyan District, Mandalay Division
2. Area
(7) Acre
3. Commissioning Date
(25-July-2007)
4. Installed Capacity
132/66/11 kV, 45 MVA (Crompton Greave, India)
132/66/11 kV, 45 MVA (Crompton Greave, India)
66/33/11 kV, 30MVA (Fortune, China)
Total 120 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Thazi Line
(2) Aggreko Line
(B) 66 kV Transmission Lines
(1) Nyaung-oo Electric River Pump Line
(2) Seik-nyan Electric River Pump Line
(3) Se-mee-Khong (1) River Pump Line
(4) Se-mee-Khong (2) River Pump Line
(5) Kyaw-ze Line
(6) Myingyan (1) Line
(7) Na-bu-I (Ministry of Industry) Line
(C) 33 kV Distribution Feeders
(1) Taung-thar Feeder
(2) Steel Mill Feeder
(3) Thar-paung River Pump Feeder
(4) Myingyan (2) Feeder
(5) Na-htoe-gyi Feeder
(6) MOGE Feeder
6. Distribution Regions
River Pumps in MyingyanTownship, Taung-thar, Ma-hlaing, Na-htoe-gyi, Nga-zoon, Myit-thar, Nyaung-oo Townships, River Pumps in Bagan Township, Myaung Township, Twin-gyi River Pump, Na-bu-I Factory, Myo-thar, Myingyan Industrial Zone
1. Location
Near Yinmarpin Cottage Village, Thazi Township, Meikhtila District, Mandalay Division
2. Area
(4.62) Acre
3. Commissioning Date
(25-November-2006)
4. Installed Capacity
132/33 kV, 15 MVA (Brush, England)
Total 15 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Yepaungsone Line
(B) 33 kV Distribution Feeders
(1) Engine Plant Feeder
(2) Ta-Ka-Sa (2) Feeder
6. Distribution Regions
No (2) Army Heavy Industry Factory, Yinmarpin Cottage, Thazi Township
1. Location
Yadanarpon Myoe-thit, Pyinoolwin District, Mandalay Division
(11.01) Acre
3. Commissioning Date
(29-November -2007)
132/33/11 kV,18 MVA (Areva, Indonesia)
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Shwesaryan Line
(B) 33 kV Distribution Feeders
(1) Northern Residential Feeder
(C) 11 kV Distribution Feeders
(1) Teleport Feeder
(2) Incubation Feeder
(3) Softbase Feeder
6. Distribution Regions
Yadanarpon Teleport, Electronic product Factory, Northern Residential, 21 mile village, Central Service of Civil Institude,Pyin-sar village, Thone-daung village, Communication Tower, Teleport Southern Residential, Cyber Hall,Police Training Center, Yadanarpon Myoe-thit Northern Residential(200 Acre)
1. Location
Thazi Township, Meikhtila District, Mandalay Division
2. Area
(61.7) Acre
3. Commissioning Date
(21-February -2010)
4. Installed Capacity
132/33/11 kV60 MVA (Baoging Tianwei, China)
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Kalaw (1) Line
(2) Kalaw (2) Line
(3) Thazi (1) Line
(4) Thazi (2) Line
(5) Yinmarpin Line
(B) 33 kV Distribution Feeders
(1) Htoo Cement Factory Feeder
(2) Shwe-daung Cement Factory Feeder
(3) YCDC Feeder
(4) Pyin-yaung Village Feeder
(5) Yinmarpin Village Feeder
6. Distribution Regions
Cement Factories, Villages
1. Location
Sin-gu Township, Pyinoolwin District, Mandalay Division
2. Area
(20.03) Acre
3. Commissioning Date
(5-September -1997)
4. Installed Capacity
132/33/11 kV,20 MVA (Imefy, Spain)
132/66/11 kV, 60 MVA (Xina XD, China)
Total 80 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Sedawgyi Line
(2) Hnagpyawdine Line
(B) 66 kV Distribution Lines
(1) Moe-gok Line
(C) 33 kV Distribution Feeders
(1) Moe-gok Feeder
(2) Sin-guu Feeder
(3) Kyauk-kyi Feeder
6. Distribution Regions
Mogok, Tha-bake-kyin, Kyauk-myaung, No (1) Science and Technology Battalion (Kyauk-kyi)
1. Location
Kyaukse Township, Kyaukse District, Mandalay Division
2. Area
(10.25) Acre
3. Commissioning Date
(17-March -2003)
4.Installed Capacity
132/33/11 kV60 MVA (Daihen, Japan)
Total 60 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Kin-dar Line
(2) Belin Line
(3) Taungdawkwin Line
(B) 33 kV Distribution Feeders
(1) MI-1(Pharm) Feeder
(2) Cotton yarn Feeder
(3) Taung-taw (Communication) Feeder
(4) MI-1(Industrial Zone) Feeder
(5) Sin-min Cement Factory Feeder
(6) Mechanized Farming Feeder
(7) Mine-maw (Tank Car) Feeder
(8) Phyuk-seik-pin Feeder
(9) Kyaukse (Mirror) Feeder
(10) Myit-thar+Kumae Feeder
6. Distribution Regions
Southern part of Kyaukse, Myit-thar Township, Ku-mae Township, Northern part of Windwin Township, Pharmaceutical Industry, Cotton yarn, Industry (1) Factories, Sin-min Cement Factory, Mechanized Farming, Mirror Factory, Taung-taw (Communication ), Phyuk-seik-pin Battalion, Min-Maw Cantonment
1. Location
Pyinoolwin Township, Pyinoolwin District, Mandalay Division
2. Area
(5.5) Acre
3. Commissioning Date
(20-November -1983)
4. Installed Capacity
132/33/11 kV,60 MVA (Areva, Indonesia)
Total 60 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Shwesaryan- Yadanarpon- Anaesakhan Line
(B) 33 kV Distribution Feeders
(1) Iron and Steel Mill (1) Feeder
(2) Iron and Steel Mill (2) Feeder
(3) Pyinoolwin Feeder
(4) Tat-tnal Feeder
(5) Ta-Tha-Na Feeder
(6) Pharmaceutical Industry Feeder
(7) Tha-Pa-Na Feeder
(8) Athanlwint Feeder
(C) 11 kV Distribution Feeders
(1) Si-thar (1) Feeder
(2) Si-thar (2) Feeder
(3) Kan-taw-gyi + Residential Feeder
6. Distribution Regions
Pyinoolwin
1. Location
Patheingyi Township, Mandalay District, Mandalay Division
2. Area
(22.52) Acre
3. Commissioning Date
(19-July-1995)
4. Installed Capacity
132/33/11 kV30 MVA (NANTONG, CHINA)
132/11 kV31.5 MVA (Changzhou, China)
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Sedawgyi Line
(2) Belin Line
(3) Tagundine Line
(B) 33 kV Distirbution Feeders
(1) Myoe-ma Feeder
(2) Industrial Training Center Feeder
(3) Htun-don Feeder
(4) War-khin-gone Feeder
(C) 11 kV Distribution Feeders
(1) Nanshae Feeder
(2) (26) Street Feeder
(3) (28) Street Feeder
(4) (35) Street Feeder
(5) Mandalay Technical University Feeder
(6) (30) Street Feeder
(7) Mahar-myaing Feeder
6. Distribution Regions
Aungmyaytharzan Township, Chanayetharzan Township, Maharaungmyay Township, Chanmyatharzi Township, Patheingyi Township
1. Location
Kyaukse Township, Kyaukse District, Mandalay Division
2. Area
(39.69) Acre
3. Commissioning Date
(3-November-2012)
4. Installed Capacity
132/33/11 kV 50 MVA (Siemens, China)
132/33/11 kV 50 MVA (Siemens, China)
132/33/11 kV 50 MVA (Siemens, China)
Total 150 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Ingone Line
(B) 33 kV Distribution Feeders
(1) AAA (Cement) Feeder
(2) Tiger Head (Cement) Feeder
(3) Myanmar Elephant (Cement) Feeder
(4) Than-taw-myat Feeder
(5) Myoe-gyi (1) Feeder
(6) Myoe-gyi (2) Feeder
6. Distribution Regions
Ywar-Ngan Township, Kyaukse Township