1 |
Location |
− |
Kyunhla Township, Sagaing Region |
2 |
River |
− |
Mue |
3 |
Construction Starting Date |
− |
1998 |
4 |
Commercial Running Date |
− |
2002 |
5 |
Installed Capacity |
− |
30 MW (3 × 10 MW) |
6 |
Rated Head |
− |
62 ft |
7 |
Type of Turbine |
− |
Kaplan (Vertical) |
8 |
Discharge |
− |
2 × 2228 ft3/s = 6684 ft3/s |
9 |
Annual Design Generation |
− |
117.2 GWh |
10 |
Transmission Line |
− |
33 kV Thaphanseik-Kantbalu Line (1) (15.21) miles 33 kV Thaphanseik- Ngapyawdaing Line (2) (19.8) miles 132 kV Thaphanseik- Ngapyawdaing Line (36) miles |
11 |
Penstock |
− |
1472 ft (f - 20 ft) |
1 |
Location |
− |
Kalay Township, Sagaing Region |
2 |
Creek |
− |
Nerinzara |
3 |
Construction Starting Date |
− |
2003-2004 |
4 |
Commercial Running Date |
− |
2015-2016 |
5 |
Installed Capacity |
− |
4 MW (2 × 2 MW) |
6 |
Type of Turbine |
− |
Francis (Horizontal) |
7 |
Annual Design Generation |
− |
21 GWh |
230 kV Transmission Line
Sagaing Division
Sr. |
Name of Transmission Line |
Conductor Size |
Distance (Mile) |
Number of Tower |
1 |
230 kV Belin - Owntaw |
605 MCM |
33.32 |
143 |
2 |
230 kV Owntaw - Nyaungpingyi |
605 MCM |
54.43 |
230 |
132 kV Transmission Lines
Sagaing Division
Sr. |
Name of Transmission Line |
Conductor Size |
Distance (Mile) |
Number of Tower |
1 |
132 kV Nyaungpingyi–Monywa (Aung Chan Thar) |
397.5 MCM |
12.65 |
68 |
2 |
132 kV Yaepangsone-Yinmarbin |
397.5 MCM |
0.57 |
5 |
3 |
132 kV Thaphansake - Hnagpyawdine |
397.5 MCM |
33.13 |
172 |
66 kV Transmission Lines
Sagaing Division
Sr. |
Name of Transmission Line |
Conductor Size |
Distance (Mile) |
Number of Tower |
1 |
66 kV Yebutalin – Kani - Mingin |
397.5 MCM |
66.79 |
937 |
33 kV Transmission Line
Sagaing Division
Sr. |
Name of Transmission Line |
Conductor Size |
Distance (Mile) |
Number of Tower |
1 |
33 kV Thaphansate-Kanbalu(1) |
400 sqmm |
15.21 |
283 |
2 |
33 kV Thaphansate-Kanbalu(2) |
400 sqmm |
14.27 |
271 |
230 kV Primary Substation (Sagaing Division) (2022, August)
No |
Substation |
Voltage ratio |
Capacity (MVA) |
Total Capacity (MVA) |
Location |
1 |
Nyaungbingyi |
230/132/11 |
100 |
200 |
Yinmarpin District, Sarrlingyi Township |
230/33/11 |
100 |
||||
2 |
Owntaw |
230/33/11 |
60 |
260 |
Sagaing District, Sagaing Township |
230/66/11 |
100 |
||||
230/33/11 |
100 |
||||
3 |
Shwebo |
230/132/11 |
100 |
200 |
Shwebo District, Shwebo Township |
230/33/11 |
50 |
||||
230/33/11 |
50 |
||||
4 |
Nabar |
230/66/11 |
50 |
100 |
Kathar District, Inndaw Township |
230/66/11 |
50 |
||||
5 |
Kalay |
230/66/11 |
50 |
100
|
Kalay District, Kalay Township
|
230/66/11 |
50 |
||||
Total capacity (MVA) |
860 |
|
132 kV Primary Substation (Sagaing Division) (2022, August)
No |
Substation |
Voltage ratio |
Capacity (MVA) |
Total Capacity (MVA) |
Location |
1 |
Kyaukpahtoe |
132/66/11 |
50 |
65 |
Kathar District, Kawlin Township |
132/33/6.6 |
15 |
||||
2 |
Hnackpyawdine |
132/33/11 |
50 |
100 |
Shwebo District, Kanbalu Township |
132/33/11 |
50 |
||||
3
|
Aungchanthar |
132/66/11 |
45 |
145 |
Monywa District, Monywa Township |
132/33/11 |
50 |
||||
132/33/11 |
50 |
||||
Total capacity (MVA) |
310 |
|
1. 230 kV Nyaungbingyi Primary Substation
1. Location
Sarrlingyi Township, Yinmarpin District, Sagaing Division
2. Area
(106.9) Acre
3. Commissioning Date
(22- November- 1981)
4. Installed Capacity
230/132/11 kV 100 MVA (Areva, China)
230/33/11 kV 100 MVA (ABB, Thailand)
Total 200 MVA
5. Transmission Lines and Distribution Lines
(A) 230 kV Transmission Lines
(1) Ohntaw (1) Line
(2) Ohntaw (2) Line
(3) Chaunggu Line
(4) Latpantaung (1) Line
(5) Latpantaung (2) Line
(B) 132 kV Transmission Lines
(1) Kyunachung Line
(2) Aungchanthar Line
(C) 33 kV Feeders
(1) Copper Industry (1) Feeder
(2) Copper Industry (2) Feeder
(3) Taxtie Factory Feeder
(4) Acid Factory Feeder
(5) Kyauk-myat River Water Pump Feeder
(6) Lat-pan-taung Feeder
(7) Lae-nguk Feeder
6. Distribution Regions
Sarr-lin-gyi, Palae, Yin-mar-bin and Kani
2. 230 kV OhnTaw Primary Substation
1. Location
Sagaing Township, Sagaing District, Sagaing Division
2. Area
(32.26) Acre
3. Commissioning Date
(20-Janauary-2010)
4. Transformer Capacity
230/33/11kV 60 MVA (LEEEC, China)
230/66/11kV 100 MVA (Areva, Indonesia)
230/33/11kV 100 MVA (ABB, Thailand)
Total 260 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Belin (1) Line
(2) Belin (2) Line
(3) Nyaungpingyi (1) Line
(4) Nyaungpingyi (2) Line
(5) ShweBo (1) Line
(6) ShweBo (2) Line
(B) 66 kV Transmission Lines
(1) Tat Ywar Line
(2) Ayar-Taw (2) Line
(3) Sin-Tatt Line
(C) 33 kV Distribution Feeders
(1) SagaingMyoe-Ma Feeder
(2) Sagaing Industrial Zone Feeder
(3) Owntaw+Sarr-Taung Feeder
(4) Ywar-Thit-Gyi Batiste and Cloth Factory Feeder
(5) (Myin-Mu)-Myaung Feeder
(6) MinKoon Feeder
6. Distribution Regions
Sagaing Township, Owntaw, Sarr-Taung, Wat-Lat, Ayar Taw,
Shwe-Bo, Ywar-Thit-Gyi, Myin-Mu, Myaung Township
3. 230 kV ShweBo Primary Substation
1. Location
Shwebo Township, Shwebo District, Sagaing Division
2. Area
(42.37) Acre
3. Commissioning Date
(2-October-2019)
4. Transformer Capacity
230/132/11kV 100 MVA (Seimens, Wuhan China)
230/33/11kV 50 MVA (Seimens, Wuhan China)
230/33/11kV 50 MVA (Seimens, Wuhan China)
Total 200 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Ohntaw (1) Line
(2) Ohntaw (2) Line
(3) Nabar (1) Line
(4) Nabar (2) Line
(B) 33 kV Distribution Feeders
(1) Shwebo (Thuzar) Feeder
(2) Shwebo Industrial Zone Feeder
(3) Khin Oo+ Ye Oo Feeder
(4) NyaungPinThar Feeder
6. Distribution Regions
ShweboTownship, Khin Oo Township, Ye Oo Township
4. 230 kV Nabar Primary Substation
1. Location
Inndaw Township, Kathar District, Sagaing Division
2. Area
(37) Acre
3. Commissioning Date
(14-1-2020)
4. Transformer Capacity
230/66/11kV 50 MVA (Seimens, Wuhan China)
230/66/11kV 50 MVA (Seimens, Wuhan China)
Total 100 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Shwebo (1) Line
(2) Shwebo (2) Line
(3) Bamaw (1) Line
(4) Bamaw (2) Line
(B) 66 kV Distribution Feeders
(1) Mohnyin Feeder
(2) Shwegu-bamaw Feeder
(3) Kyaukphahtoe Feeder
(C) 33 kV Distribution Feeders
(1) Kathar Feeder
(2) Inndaw Feeder
(3) Mawluu Feeder
6. Distribution Regions
Kathar District, Mohnyin District, Myintkyina District
5. 230 kV Nabar Primary Substation
1. Location
Kalay Township, Kalay District, Sagaing Division
2. Area
(20.93) Acre
3. Commissioning Date
(7-7-2018)
4. Transformer Capacity
230/66/11kV 50 MVA (Seimens, Wuhan China)
230/66/11kV 50 MVA (Seimens, Wuhan China)
Total 100 MVA
5. Transmission Lines and Distribution Feeders
(A) 230 kV Transmission Lines
(1) Gangaw-Kalay (1) Line
(2) Gangaw-Kalay (2) Line
(B) 66 kV Distribution Feeders
(1) YarZaJoul Feeder
(2) KalayWa Feeder
6. Distribution Regions
KalayWa Township, YarZaJoul Township,
Kalay Twonship, Kalay District
1. 132 kV Kyaukpahtoe Substation
1. Location
Kawlin Township, Kathar District, Sagaing Division
2. Area
(13.05) Acre
3. Commissioning Date
(25- September-1990)
4. Installed Capacity
132/33/6.6 kV 15 MVA (Minel, Yugoslavia)
132/66/11 kV 50 MVA (Xian XD, China)
Total 65 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Sedawgyi Line
(B) 66 kV Transmission Lines
(1) Nabar Line
(C) 33 kV Distribution Feeders
(1) Gold Factory 1 Feeder
(2) Kawlin Feeder
(3) Phelay Feeder
(4) Gold Factory 2 Feeder
(D) 6.6 kV Distribution Feeders
(1) Gold Factory 1 Feeder
6. Distribution Regions
Kawlin Township, Wintho Township, Pinlaebuu Township, Phelay,
Gold Purifying Factory, Shawphyukone village, Khanthar village
2. 132 kV HnackPyawdye Primary Substation
1. Location
Kanbalu Township, Shwebo District, Sagaing Division
2. Area
(29.83) Acre
3. Commissioning Date
(18-June-2002)
4. Installed Capacity
132/33/11 kV, 50 MVA (Fuji, Japan)
132/33/11 kV, 50 MVA (Fuji, Japan)
Total 100 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Kyaukpahtoe Line
(2) Tha-phan-seik Line
(3) Lattpanhla Line
(B) 33 kV Distribution Feeders
(1) KanbaluFeeder
(2) Shwe-boFeeder
6. Distribution Regions
Shwe-bo, Khin-oo, Yea-oo, Tant-Sel, Zee-gone, Kanbalu Township
3. 132 kV Aungchanthar Primary Substation
1. Location
Monywa Township, Monywa District, Sagaing Division
2. Area
(22.4) Acre
3. Commissioning Date
(9-June-2001)
4. Installed Capacity
132/66/11 kV45 MVA
132/33/11 kV 50 MVA (Fuji, Japan)
132/33/11 kV 50 MVA (Fuji, Japan)
Total 145 MVA
5. Transmission Lines and Distribution Feeders
(A) 132 kV Transmission Lines
(1) Nyaungpingyi Line
(B) 66 kV Distribution Lines
(1) Ya-thae-chauk River Water Pump Line
(2) Inn-taw River Water Pump Line
(3) Industry (1) Line
(C) 33 kV Distribution Feeders
(1) Myoedwin Feeder
(2) Chaung-oo+ Plywood Factory Feeder
(3) Industrial Zone Feeder
(4) Ahlone Feeder
(5) JLC Feeder
6. Distribution Regions
Monywa, Chaun-goo, A-loon-tatt Township, Bu-talin Township,
Min-kinn Township, Inn-taw River Water Pump Project Line